28 I
I - 3 Milling Specific Operations
Example: Set centerline between two workpiece edges as datum
0 is offered as a default value for the coordinate. Enter the desired
coordinate for the workpiece edge. For this example Y = 0.0, set the
coordinate as a datum for this workpiece.
8 Press the ENTER hard key.
The position of the centerline M is determined by probing the edges
1, and 2.
The centerline is parallel to the Y axis.
Desired coordinate of the centerline: X = 0.0
Spacing between edges is displayed on the message box
when using the probe centerline feature.